Seitenansicht 0
Power Blower
Operator's Manual
MODEL PB-265L
WARNING
X750009783
01/12
X7501180403
Users of this equipment risk injury to themselves and others if the unit is used im-
properly and/or safety precautions are not followed. ECHO provides an operator’s
manual. It must be read and understood for proper and safe operation. Failure to
do so could result in serious injury.
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Power Blower

Power BlowerOperator's Manual MODEL PB-265L WARNINGX75000978301/12X7501180403Users of this equipment risk injury to

Seite 2 - operaTor's manual

10assembly WARNINGNever perform maintenance or assembly procedures with engine running or serious personal injury may result.InsTall blower pIpes

Seite 3 - WARNING

11Power BloweroPerator's Manual WARNINGMoving parts can amputate ngers or cause severe injuries. Keep hands, clothing and loose objects away fr

Seite 4

12Mixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline.2. Add the proper amount of 2-stroke oil to ga

Seite 5

13Power BloweroPerator's ManualsTarTIng Cold engIne • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start-ing. Do not allo

Seite 6

14sTarTIng warm engIneThe starting procedure is the same as Cold Start except DO NOT close the choke. 1. Throttle Position Lever Move throttle po

Seite 7 - 64 Category I

15Power BloweroPerator's Manual WARNINGAlways wear safety glasses, hearing protection, face lter mask and take all safety precautions or se

Seite 8

16 WARNINGMoving parts can amputate ngers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop e

Seite 9 - ConTenTs

17Power BloweroPerator's ManualaIr fIlTerLevel 1.Parts required: REPOWERTM Air and Filter Kit 1. Close choke (Cold Start Position []). This

Seite 10 - blower pIpes / sTICk handle

18spark plugLevel 2.Parts Required: REPOWERTM Tune-Up KitIMPORTANTUse only NGK BPM8Y spark plug otherwise severe engine damage may occur. 1. Remov

Seite 11 - WARNING

19Power BloweroPerator's Manual 4. Remove engine cover. 5. Loosely install spark plug to keep dirt out of cylinder. 6. Clean cylinder

Seite 12 - DANGER

2Copyright© 2012 By Echo, IncorporatedAll Rights Reserved.Table of ConTenTsIntroduction ...

Seite 13 - Cold engIne

20Exhaust Port CleaningLevel 2Parts Required: As needed: Heat Shield 1. Remove spark plug lead from spark plug, and remove engine cover. 2. Plac

Seite 14 - engIne

21Power BloweroPerator's ManualACarbureTor adjusTmenTEngine Break-InNew engines must be operated a minimum duration of two tanks of fuel break-in

Seite 15 - blower

22 DANGERFuel vapors are extremely ammable and may cause re and/or explosion. Never test for ignition spark by ground-ing spark plug near cyli

Seite 16 - InTervals

23Power BloweroPerator's Manual WARNINGDuring operation the mufer - catalytic mufer and surrounding cover become hot. Always keep exhaust

Seite 17

24speCIfICaTIonsMODEL ---------------------------------------------------- PB-265LLength ------------------------------------------------------ 305 m

Seite 18 - CoolIng sysTem

25Power BloweroPerator's ManualECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010ECHO'S RESPONSIBILITYE

Seite 19

26PURCHASED REPAIR PARTS, SHORT BLOCKS AND ACCESSORIES

Seite 20 - Exhaust Port Cleaning

27Power BloweroPerator's Manual ECHO INCORPORATED EMISSION CONTROL WARRANTY STATEMENTFOR ECHO AND SHINDAIWA BRANDSThe Environmental Protection Ag

Seite 21 - adjusTmenT

ECHO, INCORPORATED400 OakwOOd ROadLake ZuRich, iL 60047www.echo-usa.comCONSUMER PRODUCTSUPPORT1-800-673-15588:30 - 4:30 Mon - Fri C.S.T.P07811001001/

Seite 22 - TroubleshooTIng

3Power BloweroPerator's ManualsafeTymanual safeTy symbols and ImporTanT InformaTIon Throughout this manual and on the product itself, you will n

Seite 23

4Vibration and Cold It is believed that a condition called Raynaud’s Phenomenon, which affects the ngers of certain individuals, may be brought about

Seite 24

5Power BloweroPerator's Manual DANGERDo not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poison

Seite 25

6equIpmenT CheCk WARNINGUse only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment combi-nation. ECH

Seite 26 - 11/18/2011

7Power BloweroPerator's ManualdesCrIpTIonLocate the safety decals on your unit. Make sure the decals are legible and that you understand and fol

Seite 27

8 1. SAFETY DECAL - Lists important safety precautions. 2. SAFETY DECAL - Lists important safety precautions. 3. SAFETY DECAL - Lists important saf

Seite 28 - 1-800-432-3246

9Power BloweroPerator's ManualConTenTs___ 1 - Power Head___ 1 - Flex Pipe___ 1 - Swivel Pipe___ 1 - Straight Pipe___ 1 - Straight Pipe